Applications
- Stormflow tanks
- Pump stations
- Tanks in sewage treatment plants
- Tanks in water plants
- Tanks and vessels in process and food industries.
Shuttle ultrasonic level transmitter is mainly used for ultrasonic level measurements in wastewater wells, sewer wells and drinking water tanks or reservoirs. Measurements are done without physical contact with the measured liquid. Furthermore, the transmitter can also be used for accurate measurements of water levels in canals and ports etc. Non-contact measurement is ideal for contaminated liquids, including aggressive chemicals or liquids with a very high concentration of dissolved solids or sludge.
Parameter | Specification |
---|---|
Range | 0-12 m, 0-15 m, 0-25 m (depending on sensor) |
Span | (4/20 mA) From 0-10 cm to 0-12 m/15 m/25 m |
Supply Voltage | 230/115 V AC ± 10% or 10-30 V DC |
Power Consumption | Approx. 2 W |
Temperature Range | -20° to +60°C |
Input | From ultrasonic sensor |
Measurement Accuracy | Better than ± 0.2% |
Outputs | Analog: 4 – 20 mA, max. load 500 Ω Digital: 2 x relays with programmable NO/NC function Max. 1 A resistive load @ 50 V |
Indication | LCD display with four digits and symbols |
Operation | Function keypad behind front panel |
Enclosure | IP 67 |
Test Approvals | CE: EN 50081-1, EN 50082-1 UL: File E194021 |