Range : Wind speed, Wind direction

Vaisala Weather Transmitter WXT530 series is a unique collection of cost-effective sensors that accurately and reliably measure weather conditions. They can capture any combination of wind, rain, temperature, and barometric readings in a compact, affordable package.

WXT530 models utilize solid state technologies that minimize operating and maintenance costs. Digital and analog interfaces make for easy, flexible integration, and third-party sensors can be connected to select WXT530 models to create your own weather parameter hub.

Categories ,

Applications

  • WXT530 models utilize solid state technologies that minimize operating and maintenance costs.
  • The WXT532 focusing on the wind speed, and wind direction.
  • Low power consumption is ideal for battery powered systems.

Features

  • Unique Vaisala solid state sensor technology that includes WINDCAP®
    ultrasonic wind sensors to determine horizontal wind speed and direction.
  • Wide variety of digital communication modes for easy integration with
    most weather monitoring platforms.
  • Self-diagnostics automatically validate measurement stability.
  • Optional thermostatically controlled heaters in the transducer heads and
    arms prevent build-up of freezing rain and snow for operation in cold and
    humid environments.

Specifications

Wind measurement performance

Property Description/Value
Wind speed 7
Observation range 0 … 60 m/s (134 mph)
Reporting range 0 … 75 m/s (168 mph)
Response time 0.25 s
Available variables Average, maximum, and minimum
Accuracy ±3 % at 10 m/s (22 mph)
Output resolution 0.1 m/s (km/h, mph, knots)
Units available m/s, km/h, mph, knots
Wind direction 7
Azimuth 0 … 360°
Response time 0.25 s
Available variables Average, maximum, and minimum
Accuracy ±3.0° at 10 m/s (22 mph)
Output resolution
Averaging time 1 … 3600 s, sample rate 1, 2, or 4 Hz (configurable)

Inputs and outputs

Property Description/Value
Operating voltage 6 … 24 V DC (−10 … +30 %)
Average power consumption Minimum: 0.1 mA at 12 V DC (SDI‑12 standby)
Typical: 3.5 mA at 12 V DC (typical measuring intervals) 8
Maximum: 15 mA at 6 V DC (constant measurement of all parameters)
Heating voltage DC, AC, or full-wave rectified AC
12 … 24 V DC (−10 … +30 %)
12 … 17 V ACrms (−10 … +30 %)
Typical heating current 12 V DC: 800 mA, 24 V DC: 400 mA
12 V ACrms: 1.1 A
17 V ACrms: 800 mA
Digital outputs SDI‑12, RS‑232, RS‑485, RS‑422
Communication protocols SDI‑12 v1.3, Modbus RTU, ASCII automatic and polled, NMEA 0183 v3.0 with query option
Self-diagnostic Separate supervisor message, unit/status fields to validate measurement stability
Startup Automatic, < 5 seconds from power on to the first valid output

WXT536 analog input options

Parameter Element Range Input 9 Excitation Resolution
Temperature (Pt1000) Resistor 800 … 1330 Ω 2‑wire
4‑wire
2.5 V 16 bits
Solar radiation Thermopile 0 … 25 mV 4 MΩ 12 bits
Voltage input Voltage 0 … 2.5 V
0 … 5 V
0 … 10 V
> 10 kΩ 12 bits
Tipping bucket rain gauge Frequency 0 … 100 Hz 18 kΩ 3.5 V

WXT530 analog mA output options

Parameter Description/Value
Wind speed 0 … 20 mA or 4 … 20 mA
Wind direction 0 … 20 mA or 4 … 20 mA
Load impedance Max. 200 Ω
Update interval Max. 4 Hz

Operating environment

Property Description/Value
Operating environment Outdoor use
Operating temperature −52 … +60 °C (−60 … +140 °F)
Storage temperature −60 … +70 °C (−76 … +158 °F)
Operating humidity 0 … 100 %RH
Operating pressure 500 … 1100 hPa
Wind 0 … 60 m/s (0 … 134 mph)
IP rating Without mounting kit: IP65 – Dust-tight. Protected from water jets from any direction.
With mounting kit: IP66 – Dust-tight. Protected from powerful water jets from any direction.

Mechanical specifications

Property Description/Value
Weight
WXT534, WXT535, WXT536 0.7 kg (1.54 lb)
WXT531, WXT532, WXT533 0.5 kg (1.1 lb)
Materials
Radiation shield, top, and bottom parts Polycarbonate +20 % fiberglass
Precipitation sensor plate Stainless steel (AISI 316)

Compliance

Property Description/Value
EU directives and regulations EMC Directive (2014/30/EU)
RoHS Directive (2011/65/EU) amended by 2015/863
Electromagnetic compatibility (EMC) EN 61326‑1, industrial environment
CISPR 32 / EN 55032, Class B
Environmental IEC 60068‑2‑1, 2, 6, 14, 30, 31, 78
IEC 60529, VDA 621‑415
Maritime IEC 60945 (Exposed)
DNV GL Type Examination Certificate No. TAA00000VF
Compliance marks CE, RCM, RoHS, China RoHS, UKCA