Specifications
Barometric pressure measurement performance
Property |
Description/Value |
Observation range |
500 … 1100 hPa |
Accuracy (for sensor element) at 600 … 1100 hPa |
- ±0.5 hPa at 0 … +30 °C (+32 … +86 °F)
- ±1 hPa at −52 … +60 °C (−60 … +140 °F)
|
Output resolution |
0.1 hPa / 10 Pa / 0.001 bar / 0.1 mmHg / 0.01 inHg |
Units available |
hPa, Pa, bar, mmHg, inHg |
Air temperature measurement performance
Property |
Description/Value |
Observation range |
−52 … +60 °C (−60 … +140 °F) |
Accuracy (for sensor element) at +20 °C (+68 °F) |
±0.3 °C (±0.54 °F) |
Output resolution |
0.1 °C (0.1 °F) |
Units available |
°C, °F |
Relative humidity measurement performance
Property |
Description/Value |
Observation range |
0 … 100 %RH |
Accuracy (for sensor element) |
±3 %RH at 0 … 90 %RH
±5 %RH at 90 … 100 %RH |
Output resolution |
0.1 %RH |
PTU measuring interval |
1 … 3600 s (= 60 min), at 1 s steps |
Precipitation measurement performance
Property |
Description/Value |
Collecting Area |
60 cm² (9.3 in²) |
Rainfall Output Resolution |
0.01 mm (0.001 in) |
Field Accuracy for Daily Accumulation |
Better than 5%, weather-dependent |
Units Available |
mm, in |
Duration |
Counting each 10-second increment whenever droplet detected |
Duration Output Resolution |
10 s |
Intensity |
Running 1-minute average, 10 s steps |
Intensity Observation Range |
0 … 200 mm/h (0 … 7.87 in/h) (broader with reduced accuracy) |
Intensity Output Resolution |
0.1 mm/h (0.01 in/h) |
Units Available (Intensity) |
mm/h, in/h |
Hail Output Resolution |
0.1 hits/cm² (1 hits/in²), 1 hit |
Units Available (Hail) |
hits/cm², hits/in², hits |
Intensity Output Resolution (Hail) |
0.1 hits/cm²h (1 hits/in²h), 1 hit/h |
Units Available (Intensity – Hail) |
hits/cm²h, hits/in²h, hits/h |
Wind measurement performance
Property |
Description/Value |
Wind speed 7 |
Observation range |
0 … 60 m/s (134 mph) |
Reporting range |
0 … 75 m/s (168 mph) |
Response time |
0.25 s |
Available variables |
Average, maximum, and minimum |
Accuracy |
±3 % at 10 m/s (22 mph) |
Output resolution |
0.1 m/s (km/h, mph, knots) |
Units available |
m/s, km/h, mph, knots |
Wind direction 7 |
Azimuth |
0 … 360° |
Response time |
0.25 s |
Available variables |
Average, maximum, and minimum |
Accuracy |
±3.0° at 10 m/s (22 mph) |
Output resolution |
1° |
Averaging time |
1 … 3600 s, sample rate 1, 2, or 4 Hz (configurable) |
Inputs and outputs
Property |
Description/Value |
Operating voltage |
6 … 24 V DC (−10 … +30 %) |
Average power consumption |
Minimum: 0.1 mA at 12 V DC (SDI‑12 standby)
Typical: 3.5 mA at 12 V DC (typical measuring intervals) 8
Maximum: 15 mA at 6 V DC (constant measurement of all parameters) |
Heating voltage |
DC, AC, or full-wave rectified AC
12 … 24 V DC (−10 … +30 %)
12 … 17 V ACrms (−10 … +30 %) |
Typical heating current |
12 V DC: 800 mA, 24 V DC: 400 mA
12 V ACrms: 1.1 A
17 V ACrms: 800 mA |
Digital outputs |
SDI‑12, RS‑232, RS‑485, RS‑422 |
Communication protocols |
SDI‑12 v1.3, Modbus RTU, ASCII automatic and polled, NMEA 0183 v3.0 with query option |
Self-diagnostic |
Separate supervisor message, unit/status fields to validate measurement stability |
Startup |
Automatic, < 5 seconds from power on to the first valid output |
WXT536 analog input options
Parameter |
Element |
Range |
Input 9 |
Excitation |
Resolution |
Temperature (Pt1000) |
Resistor |
800 … 1330 Ω |
2‑wire
4‑wire |
2.5 V |
16 bits |
Solar radiation |
Thermopile |
0 … 25 mV |
4 MΩ |
– |
12 bits |
Voltage input |
Voltage |
0 … 2.5 V
0 … 5 V
0 … 10 V |
> 10 kΩ |
– |
12 bits |
Tipping bucket rain gauge |
Frequency |
0 … 100 Hz |
18 kΩ |
3.5 V |
– |
WXT530 analog mA output options
Parameter |
Description/Value |
Wind speed |
0 … 20 mA or 4 … 20 mA |
Wind direction |
0 … 20 mA or 4 … 20 mA |
Load impedance |
Max. 200 Ω |
Update interval |
Max. 4 Hz |
Operating environment
Property |
Description/Value |
Operating environment |
Outdoor use |
Operating temperature |
−52 … +60 °C (−60 … +140 °F) |
Storage temperature |
−60 … +70 °C (−76 … +158 °F) |
Operating humidity |
0 … 100 %RH |
Operating pressure |
500 … 1100 hPa |
Wind |
0 … 60 m/s (0 … 134 mph) |
IP rating |
Without mounting kit: IP65 – Dust-tight. Protected from water jets from any direction.
With mounting kit: IP66 – Dust-tight. Protected from powerful water jets from any direction. |
Mechanical specifications
Property |
Description/Value |
Weight |
WXT534, WXT535, WXT536 |
0.7 kg (1.54 lb) |
WXT531, WXT532, WXT533 |
0.5 kg (1.1 lb) |
Materials |
Radiation shield, top, and bottom parts |
Polycarbonate +20 % fiberglass |
Precipitation sensor plate |
Stainless steel (AISI 316) |
Compliance
Property |
Description/Value |
EU directives and regulations |
EMC Directive (2014/30/EU)
RoHS Directive (2011/65/EU) amended by 2015/863 |
Electromagnetic compatibility (EMC) |
EN 61326‑1, industrial environment
CISPR 32 / EN 55032, Class B |
Environmental |
IEC 60068‑2‑1, 2, 6, 14, 30, 31, 78
IEC 60529, VDA 621‑415 |
Maritime |
IEC 60945 (Exposed)
DNV GL Type Examination Certificate No. TAA00000VF |
Compliance marks |
CE, RCM, RoHS, China RoHS, UKCA |